Water Filtration and Purification Equipment Supplier

Reverse Osmosis System Parts and Supplier

Commercial and Residential Wave Cyber DI & Pressure Tanks Supplier

Water Filtration Manufacturer Distributor Vendor Water Purification

Vontron RO Nanofiltration Ultrafiltration Membrane Distributor

Ultrafiltration Membrane Elements

Spiral Wound Ultrafiltration Membrane Elements: VUF Series

Introduction

VUF Series ultrafiltration membrane is spiral wound polyether sulfone membrane element. It has the characteristics of high heat resistance and chemical stability, uniform pore size and high molecule cut off accuracy. The VUF series ultrafiltration membrane is welded by rotary welding process, which ensures very low fluid resistance and high durability of the membrane element.

Introduction

VUF series ultrafiltration membrane can effectively remove proteins, viruses, macromolecular organics, pigments, polysaccharides and other macromolecular from water, and permeate inorganic salts, micromolecular pigments, monosaccharides and other micromolecular substances and water. It also can be used for separating different molecular weight materials to achieve the purpose of decolorization, purification and separation and concentration. VUF series ultrafiltration membranes are mainly used in the treatment of electronic ultrapure water, drinking water, municipal water and various industrial water, the pretreatment of RO system, and the separation and concentration of materials in biochemical, pharmaceutical and food industry.

The VUF series is mainly used for separation and concentration of specific material with molecular weight cut off (MWCO) at 4k, 6k, 8k, 10k, 20k, 67k Da. VUF series applies the feed channel spacer of 31, 46 and 90mil, and is favorably equipped with the fiberglass housing of sanitary-grade housing.

Active Membrane Area ft2(m²): 400 (37.2) 
Permeate Flow Rate GPD (m³/d): 8700 (32.9) 
Testing Solution (%): PEG4000
Operating Pressure: 60 psi (0.41Mpa)
Active Membrane Area ft2(m²): 400 (37.2) 
Permeate Flow Rate GPD (m³/d): 6500 (24.6) 
Testing Solution (%): PEG6000
Operating Pressure: 60 psi (0.41Mpa)
Active Membrane Area ft2(m²): 400 (37.2) 
Permeate Flow Rate GPD (m³/d): 9500 (35.9) 
Testing Solution (%): PEG8000
Operating Pressure: 60 psi (0.41Mpa)
Active Membrane Area ft2(m²): 400 (37.2) 
Permeate Flow Rate GPD (m³/d): 7000 (26.5) 
Testing Solution (%): PEG10000
Operating Pressure: 40 psi (0.28Mpa)
Active Membrane Area ft2(m²): 400 (37.2) 
Permeate Flow Rate GPD (m³/d): 10500 (39.7) 
Testing Solution (%): PEG20000
Operating Pressure: 40 psi (0.28Mpa)
Model: VUF8040-67K
Active Membrane Area ft2(m²): 400 (37.2) 
Permeate Flow Rate GPD (m³/d): 25000 (94.6) 
Testing Solution (%): BSA

Spec Sheet:

Spec Sheet:

Spec Sheet:

Spec Sheet:

Spec Sheet:

Spec Sheet:

Get a Price Quote
Spiral Wound Ultrafiltration Membane: VUF Series

Thanks! We’ll send you a price quote shortly.