SLW Series Order Form
SLW SERIES
SLW 2/2-WAY DIRECT ACTING SMALL TYPE SOLENOID VALVE
-
SLW Series Normally Closed
-
Closed when de-energized open, open when energized
-
Body material: Brass, Stainless Steel, Plastic
-
Response time: 10~20ms
-
​Seals: NBR, VITON, and EPDM
-
Media: Pure Water, Air
-
Max Working Pressure: 30 bar
-
Fluid temp.: 0~100°C Ambient temp.: -10~+40°C
-
Voltage: AC220V 110V 24V 50/60Hz DC24V DC12V
-
Flow as the arrow, mounts in any position; best position is solenoid vertical and upright direction
External Dimensions Chart
Valve Selection List
External Dimensions Chart
Valve Selection List
SLW Series Order Form
SLW SERIES
SLW 2/2-WAY DIRECT ACTING SMALL TYPE SOLENOID VALVE
-
SLW Series 2/2-Way solenoid valve, closed when de-energized, open when energized
-
Serialized products, small size, large flow rate
-
Body material: Brass, Plastic
-
Open & Closed Response time: 6~20ms
-
​Seals: NBR, VITON, and EPDM
-
Media: Water, Air
-
Media temp.: 0~80°C Ambient temp.: -10~+40°C
-
Voltage: AC220V 110V 24V 50/60Hz DC24V DC12V
-
Voltage Tolerance: -10%~+10%
External Dimensions Chart
Valve Selection List
External Dimensions Chart
SLPW Series Order Form
SLPW SERIES
SLPW 2/2-WAY LOW POWER SOLENOID VALVE • NORMALLY CLOSED
-
Closed when de-energized
-
Lower power consumption, low temperature rising
-
Body Material: Brass
-
Seals: NBR, VITON, EPDM
-
Fluid Media: Only for Air or Inert Gas
-
Operating Pressure: 0~9bar
-
Media Temperature: 0~+65°C
-
Ambient Temperature: 0~+60°C
-
Ed100%, F Class
-
Important: If the current leakage of the system is more than 7ma, the Solenoid Valve will not operate properly
-
Eg: 24 VDC. 18wg multi-core wire
-
Rated voltage 24VDC, longest wiring length: 6 meters, max loop resistance 88 Ω
-
Rated voltage 24VDC, longest wiring length: 4.5 meters, max loop resistance 64 Ω
-
Rated voltage 24VDC, longest wiring length: 2.8 meters, max loop resistance 41 Ω
-
Rated voltage 24VDC, longest wiring length: 1.1 meters, max loop resistance 17 Ω
​​
-
Standard voltage: 24VDC 12VDC
-
Voltage Tolerance:-10%~+10%
-
Power consumption: 1.4w
-
Standard Coil: Lead Wires (N)
-
Mounting: Mounts in any position; best position is solenoid vertical and upright direction
External Dimensions Chart
Valve Selection List
SLB Series Order Form
SLB SERIES
SLB 2/2-WAY HIGH (LOW) TEMPERATURE SOLENOID VALVE • NORMALLY CLOSED
-
SLB series solenoid valve it is serialized products, large flow rate, good applicability, widely used in steam, oil, and the other high & low temperature liquid control
-
Adopted high temperature resistance seal material - PTFE (which material import), when the media passage, the properties is good
-
Coils type: high temperature resistance coil meanwhile it has the heat conduction protection
-
Ensure the long life time and high reliability
Main Technical Parameters
-
2/2-Way Solenoid Valve, closed when de-energized, open when energized
-
Main material: Body: Forged Brass / SST Component: Stainless Steel
-
Seal material: TEFLON
-
Ambient Temp.: -20~65°C
-
Operating pressure: 0~50.0kgf/cm²
-
Media temp.: Low temp.: -100°C~-10°C High temp.: 99°C~200°C
-
Media: High temperatures: steam, heat conducting oil and so on low temperatures: n², O², CO², attention: under the Natural temperature, such as air, water, and the other media, please choose the other economy & suitable solenoid valve
-
Voltage: AC24V / 110V 240V / 230V 50/60hz DC12V / 24V, power consumption: AC27VA (16W) DC24W, Voltage tolerance: -10%~+10%, coil type: W (normal) A=Din standard, metallic housing, safety series: class h heat resistance coil, ip 65
-
Install: Flow as the arrow, solenoid vertical and upright direction, if media has the granule impurity, please install more than 60 mesh filter
External Dimensions Chart
Valve Selection List
SLB Series Order Form
SLB SERIES
SLB 2/2-WAY HIGH (LOW) TEMPERATURE SOLENOID VALVE • NORMALLY CLOSED
-
SLB series solenoid valve it is serialized products, large flow rate, good applicability, widely used in steam, oil, and the other high & low temperature liquid control
-
Adopted high temperature resistance seal material - PTFE (which material import), when the media passage, the properties is good
-
Coils type: high temperature resistance coil meanwhile it has the heat conduction protection
-
Ensure the long life time and high reliability
Main Technical Parameters
-
2/2-Way Solenoid Valve, closed when de-energized, open when energized
-
Main material: Body: Forged Brass /SST Component: Stainless Steel
-
Seal material: TEFLON
-
Ambient Temp.: -20~65°C
-
Pressure: 1.0~15.0kgf/cm² (Low temp) 1~10kgf/cm² (Steam)
-
Media temp.: Low temp.: -100°C~-10°C High temp.: 99°C~185°C
-
Media: High temperatures: steam, heat conducting oil and so on low temperatures: N², O², CO², attention: under the Natural temperature, such as air, water, and the other media, please choose the other economy & suitable solenoid valve
-
Voltage: AC24V / 110V 240V / 230V 50/60hz DC12V / 24V, power consumption: AC27VA (16W) DC24W, Voltage tolerance: -10%~+10%, coil type: W (normal) A=Din standard, metallic housing, safety series: class h heat resistance coil, IP 65
-
Install: Flow as the arrow, solenoid vertical and upright direction, if media has the granule impurity, please install more than 60 mesh filter
External Dimensions Chart
Valve Selection List
External Dimensions Chart
Valve Selection List
SLBW Series Order Form
SLBW SERIES
SLBW 2/2-WAY CRYOGENIC SOLENOID VALVE • NORMALLY CLOSED
-
2/2-Way normally closed cryogenic solenoid valve, Closed when de-energized, Open when energized
-
Fluid temperature: -196°C ~ 110°C
-
Ambient temperature: -20°C~65°C
-
Voltage: AC220V DC24V
-
Body material: SS316
-
Seal material: PTFE
-
Orifice: 2.0~6.0mm
-
Pipe size: 1/8"~1/2"
-
Working pressure: 0~80Bar
-
Fluid: cryogenic liquid oxygen, liquid carbon dioxide, liquid nitrogen and other low temperature non-corrosive liquid
-
Flow as the arrow. Best position is solenoid vertical and upright direction
External Dimensions Chart
Valve Selection List
SAV Series Order Form
SAV SERIES
SAV DIRECT ACTING GAS SOLENOID VALVE
SAV series gas solenoid valve used in the Burner, Hear Equipment, Industrial Furnace and so on of the gas or air media. So as to achieve the procedure control or long-distance control of systems and equipment.
Main Technical Parameters
-
Direct acting zero differential, large flow rate
-
2-way normally closed solenoid valve, closed when de-energized, open when energized
-
Open and closed time: < 1 second
-
Material: main valve body material: die-casting aluminum, Others: Stainless steel/Brass
-
Seal material: VITON
-
Media: coal, gas, natural gas, air, and the other normal non-etchant gas
-
Media temp.: <65°C ambient temp.: 0~50°C
-
Voltage: DC12V DC24V AC220V/50Hz Class: H ed 100%
-
It can use explosion-proof coil, ex class: Ex mb IIC T4 Gb
-
Install: flow as the arrow, solenoid vertical and upright direction
-
Parts of coil can fix SM coil. AC220V/AC110V/AC24V/DC24V
External Dimensions Chart
Valve Selection List
SCF Series Order Form
SCF SERIES
SCF FUEL GAS EMERGENCY CUT OFF SOLENOID VALVE
Product Characteristics
-
SCF series is the normally open valve
-
When the accident happens, coils has energized through the internal spring instruction reaction, the valve quickly closes. After the accident is dealt with press the black button so the valve will open and continue working.
Main Technical Parameters
-
2/2-Way solenoid Valve
-
Body: Forged Brass
-
Seals: VITON
-
Media: Gas, Natural Gas, LPG, Etc.
-
Ambient temp.: -15°C~+60°C
-
Voltage:: DC12V, DC24V, AC220V/50Hz
-
On/Off: <1S
-
Max. Pressure: 500mbar
-
Mounting: Flow as arrow
External Dimensions Chart
Valve Selection List
SCF SERIES
SCF LARGE DIAMETER EMERGENCY CUT OFF SOLENOID VALVE
Main Technical Parameters
-
2/2-Way solenoid Valve
-
Body: Iron
-
Seals: VITON
-
Media: Gas, Natural Gas, LPG, Etc.
-
Ambient temp.: -15°C~+60°C
-
Voltage: DC12V, DC24V, AC220V/50Hz
-
On/Off: <1S
-
Working Pressure: 0~6mbar
-
Mounting: Flow as arrow