top of page

SCFT Series Order Form

SCFT Series  Solenoid Valve

Position Description

Valve Series

Valve
Series

Mode of
Operation

Coil
Type

Coil
Class

Voltage

Seal
Material

Body
Material

Pipe
Size

Orifice
(mm)

Options

1

2

3

4

5

6

7

8

9

10

Mode of Operation
Coil Class
Coil Type
Voltage
Seal Material
Pipe Size
Orifice (mm)
Body Material
Options

Thanks! We’ll send you a price quote shortly.

SCFT SERIES

SCFT SERIES GAS EMERGENCY SHUTOFF SOLENOID VALVE 

SCFT gas emergency Shut-off valve is divided into normally closed type and normally open type. When the normally closed shut-off valve is in the open state of the solenoid valve, the coil needs to be energized at the same time. When the coil is powered off, the solenoid valve is closed; Normally open type: when the solenoid valve is opened, the coil does not need to be energized, and when it is closed, only the coil needs to be momentarily energized. Both normally closed and Normally open shut-off valve require manual opening of the solenoid valve. Normally closed shut-off valves require manual opening of the solenoid valve. Normally closed shut-off valve shall be powered on the coil first and then manually opened; Normally open type does not need to energize the coil, and can be opened manually.

Technical Parameters

  • Body material: Aluminum Alloy

  • Seal Material: VITON

  • Applicable media: Gas, Natural Gas, Liquefied petroleum gas, etc.

  • Ambient temp.: -10~60°C

  • Coil: SM Coil, AC220V, DC24V

  • Maximum Working Pressure: 360mbar

  • Turn-off time: <1s

  • Diameter: Φ19mm

  • Flow as the arrow, best position is solenoid vertical and upright direction

SCFT Series Gas Emergency Shutoff Solenoid Valve

External Dimensions Chart

External Dimension

Valve Selection List

Valve Selection

Valve Selection List

Valve Selection 2

SLE Series Order Form

SLE Series  Solenoid Valve

Position Description

Valve Series

Valve
Series

Mode of
Operation

Coil
Type

Coil
Class

Voltage

Seal
Material

Body
Material

Pipe
Size

Orifice
(mm)

1

2

3

4

5

6

7

8

9

Mode of Operation
Coil Class
Coil Type
Voltage
Seal Material
Pipe Size
Orifice (mm)
Body Material

Manifold

10

Manifold

Thanks! We’ll send you a price quote shortly.

SLE SERIES

SLE MANIFOLD TYPE SERIES SOLENOID VALVE 

  • 2-Way normally closed solenoid valve; closed when energized, open when energized

  • Body Material: Brass / Aluminum (Standard)

  • Ambient Temp.: 0°C~65°C; flow as the arrow, one inlet many outlets(N)

  • Coil can fix Germany NASS Coil, standard voltage: 220VAC / 230VAC / 24VAC 50/60Hz 22VA / 24VA / 24VDC  13W

SLE Manifold Type Series Solenoid Valve

External Dimensions Chart

External Dimension
SLE Manifold Type Series Solenoid Valve

Valve Selection List

Valve Selection

SLE Series Order Form

SLE Series  Solenoid Valve

Position Description

Valve Series

Valve
Series

Mode of
Operation

Coil
Type

Coil
Class

Voltage

Seal
Material

Body
Material

Pipe
Size

Orifice
(mm)

1

2

3

4

5

6

7

8

9

Mode of Operation
Coil Class
Coil Type
Voltage
Seal Material
Pipe Size
Orifice (mm)
Body Material

10

Composition

Composition

CALL OR MESSAGE FOR ADDITIONAL PIPE SIZE OPTIONS

Thanks! We’ll send you a price quote shortly.

SLE SERIES

SLE MANIFOLD TYPE SOLENOID VALVE 

Main Technical Parameters

  • 2-Way solenoid valve normally closed, closed when de-energized, open when energized

  • One inlet many outlets(n); two inlets many outlets(n)

​

  • Body material: Brass

  • Internal component: Stainless Steel

  • Seal: NBR (media temp.: < = 80°C)

                  EPDM (media temp.: < = 120°C)

                  VITON (media temp.: < = 120°C)

  • Operating media: Water, Hot Water, Gas, Oil (< = 20cst)

  • Orifice: Φ10.0mm

  • Connection: Outlet Connection: 1/4"  3/8"  1/2"

                                 Inlet Connection: 1/2"

  • Operating Pressure: 0~13kgf/cm²

  • Voltage: AC220V  110V  24V  50/60Hz  DC24V  12V

  • Power Consumption: AC22VA  (13W)  DC13W

  • Voltage Tolerance: -10%~+10%

  • Coil type: D = DIN Standard Connections Fully Encapsulated

                           N = Lead Wires

  • Coils can use NASS Coil

  • Heat resistant class: Class F 155°C  Ed100%

  • Ambient Temp.: 0~65°C

​

SLE Manifold Type Series Solenoid Valve

External Dimensions Chart

External Chart
External Chart 2

SLJ Series Order Form

SLJ Series  Solenoid Valve

Position Description

Valve Series

Valve
Series

Mode of
Operation

Coil
Type

Coil
Class

Voltage

Seal
Material

Body
Material

Pipe
Size

Orifice
(mm)

Options

1

2

3

4

5

6

7

8

9

10

Mode of Operation
Coil Class
Coil Type
Voltage
Seal Material
Pipe Size
Orifice (mm)
Body Material
Options

Thanks! We’ll send you a price quote shortly.

SLJ SERIES

SLJ PLATE TYPE, INTERGRATED SERIES SOLENOID VALVE 

SLJ1 Normally Closed 3/2-Way Series

SLJ2 Normally Open 3/2-Way Series

SLJ3 Universal 3/2-Way Series

SLJ4 2/2-Way Series

Product Characteristics

SLJ 3/2-Way Series solenoid valve structure compact, installed in integrated plate, Realize the piping to be not moved. Optional installation exchange solenoid valves, according to the requirement of customer mix of integration (At the same time, install 2/2-Way and 3/2-Way solenoid valve on one plate). This product widely used for cylinder valve etc. implementation of the automatic control and air compressor

SLJ Plate Type, Integrated Series Solenoid Valve
SLJ Plate Type, Integrated Series Solenoid Valve

SLJ SERIES

SLJ1 NORMALLY CLOSED 3/2-WAY SERIES

Valve Selection List

Valve Selection SLJ1

External Dimensions Chart

External Dimension SLJ 1

SLJ SERIES

SLJ2 NORMALLY OPEN 3/2-WAY SERIES

Valve Selection List

Valve Selection SLJ2

External Dimensions Chart

External Dimension SLJ 2

SLJ SERIES

SLJ3 UNIVERSAL 3/2-WAY SERIES

Valve Selection List

Valve Selection SLJ3

External Dimensions Chart

External Dimension SLJ 3

SLJ SERIES

SLJ4 2/2-WAY SERIES

Valve Selection List

Valve Selection SLJ4

External Dimensions Chart

External Dimension SLJ 4

SLM Series Order Form

SLM Series  Solenoid Valve

Position Description

Valve Series

Valve
Series

Mode of
Operation

Coil
Type

Coil
Class

Voltage

Seal
Material

Body
Material

Pipe
Size

Orifice
(mm)

Options

1

2

3

4

5

6

7

8

9

10

Mode of Operation
Coil Class
Coil Type
Voltage
Seal Material
Pipe Size
Orifice (mm)
Body Material
Options
Pipe Size
Orifice (mm)
Body Material
Pipe Size
Orifice (mm)
Pipe Size
Orifice (mm)

Thanks! We’ll send you a price quote shortly.

SLM 2/2-Way Direct Acting Compact  Series Solenoid Valve • Brass
SLM 2/2-Way Direct Acting Compact  Series Solenoid Valve • SST

Valve Selection List

Valve Selection

SLM SERIES

SLM 2/2-WAY DIRECT ACTING COMPACT  SERIES SOLENOID VALVE 

  • 2/2-Way solenoid valve, Closed when de-energized, Open when energized

  • Serialized products, small in size, Large flow rate, widely used

  • Body material: Brass, SS316

  • Plunger tube material: Brass, Stainless Steel

  • Ambient temp.: 0~65°C  Fluid temp.: 0~120°C

  • Voltage: AC220V  DC24V/6W (other voltage can be special made)

  • Flow as the arrow. Best position is solenoid vertical and upright direction

  • This series valves are offered in NBR, VITON, EPDM for series and diaphragm to provide on-off control of various fluids

External Dimensions Chart

External Dimension SLM

SLM SERIES

SLM 2/2-WAY PILOT SOLENOID VALVE 

  • Product features: small size, low power, wide range of application

  • Body material: Brass and SST

  • Ambient Temp.: 0°C~65°C  Fluid Temp.: 0°C~120°C

  • Voltage: AC220V/6W  DC24V/6W (other voltages can be customized)

  • Flow as the arrow, mounts in any position; best position is solenoid vertical and upright

  • Sealing: NBR, EPDM, VITON

SLM 2/2-Way Pilot Solenoid Valve • Brass
SLM 2/2-Way Pilot Solenoid Valve • SST

Valve Selection List

Valve Selection

External Dimensions Chart

External Dimension

SLM Series Order Form

SLM Series  Solenoid Valve

Position Description

Valve Series

Valve
Series

Mode of
Operation

Coil
Type

Coil
Class

Voltage

Seal
Material

Body
Material

Pipe
Size

Orifice
(mm)

Options

1

2

3

4

5

6

7

8

9

10

Mode of Operation
Coil Class
Coil Type
Voltage
Seal Material
Pipe Size
Orifice (mm)
Body Material
Options

Thanks! We’ll send you a price quote shortly.

SLM SERIES

SLM 2/2-WAY MINIATURE DIRECT ACTING PLASTIC SOLENOID VALVE  

  • Product features: small size, low power, wide range of application

  • Body material: PPS

  • Material of tube: Stainless Steel

  • Ambient temp.: 0°C~65°C  Fluid temp.: 0°C~65°C

  • Voltage: AC220V/6VA  DC24V/6W (other voltage can be customized)

  • Connection mode: Quick insert ( Φ6.35mm ) G: 1/8

  • Flow as the arrow, mounts in any position; best position is solenoid vertical and upright direction

  • Seal: NBR, EPDM, VITON

SLM 2/2-Way Miniature Direct Acting Plastic Solenoid Valve

External Dimensions Chart

External Dimension

Valve Selection List

Valve Selection

SLVM Series Order Form

SLVM Series  Solenoid Valve

Position Description

Valve Series

Valve
Series

Mode of
Operation

Coil
Type

Coil
Class

Voltage

Seal
Material

Body
Material

Pipe
Size

Orifice
(mm)

Options

1

2

3

4

5

6

7

8

9

10

Mode of Operation
Coil Class
Coil Type
Voltage
Seal Material
Pipe Size
Orifice (mm)
Body Material
Options

Thanks! We’ll send you a price quote shortly.

SLVM SERIES

SLVM 3/2-WAY DIRECT ACTING COMPACT SERIES SOLENOID VALVE  

Main Technical Parameters

  • 3/2-Way solenoid valve, Closed when de-energized, open when energized

  • Serialized products, small in size, Large flow rate, widely used.

  • Body material: Brass

  • Plunger tube material: Brass, Stainless Steel

  • Ambient temp.: 0~65°C  Fluid Temp.: 0~120°C

  • Voltage: AC220V  DC24V/6W (other voltage can be special made)

SLVM 3/2-Way Direct Acting Compact Solenoid Valve • Brass

SLVM1 Normally Closed

SLVM2 Normally Open

SLVM3 Diverting

SLVM4 Universal​

SLVM 3/2-Way Direct Acting Compact Solenoid Valve • SST

External Dimensions Chart

Dimension Chart

SLVM1 Normally Closed

Normally Closed Chart

Normally Closed

Normally Closed Flow Chart.png

SLVM2 Normally Open

Normally Open Chart

Normally Open

Normally Open Flow Chart

SLVM3 Diverting

Diverting Chart

Diverting

Diverting Flow Chart

SLVM4 Universal

Universal Chart

Universal

Universal Flow Chart

DMF-Z SERIES

DMF-Z RIGHT ANGLE TYPE LATCHING SOLENOID VALVE  

Product Purpose

Pulse solenoid valve (also called diaphragm valve), it is the "switch" injection control instrument by pulse output signal of the control of the filter bag one row (room) injection out dust. Make the resistance of the filter to keep in the scope of the set inside, in order to ensure that the filter processing power and dust collecting efficiency.

DMF-Z type pulse valve as right Angle type valve, The Angle between import and export if 90°, suitable for air bag dust and the installation of the windy spray connection. Airflow unobstructed, can meet the requirements of the clear grey gas pulse.

Working Principle

The pulse valve diaphragm is divided into two, gas chamber (Front & Back), when switching compressed air, Compressed air through the throttle orifice into the gas chamber after at this time gas chamber pressure will diaphragm components.

​

Close to the valve outlets, pulse valve is in "closed" status. Pulse injection control instrument signal that the pulse valve bit back, after the gas Room put stomatal open, and the gas chamber pressure loss after quickly, diaphragm components moved, the compressed air. A valve lose export injection, pulse valve in the "open" status. Pulse injection control instrument signal disappears, solenoid  pulse valve bit reset, gas after.

​

Room put stomatal closure, the gas chamber pressure after increase is clingy valve diaphragm components of outlets, solenoid pulse valve and in "closed" status.

​

DMF-Z Right Angle Type Latching

3/4"~2 1/2"

 

Select your product:

Thanks for ordering!

DMF-Z Right Angle Type Latching Solenoid Valve • SST

DMF-Z Series
Valve Series: DMF-Z
Function: Right Angle Type
Seal Material:
NBR
Body Material: Aluminum
Pipe Size: 3/4"~2 1/2"

Orifice: 20 ~ 62mm 
CV
Factor: 7.6 - 52 

Model Implication

Valve Selection List

Valve Selection

Construction, External Dimension Chart

External Dimension Chart

Structure Size

Structure Size

Installation method

Solenoid  pulse valve input(IN) and air bag is connected to the metal the input termed filter in connection with spray wind connection between thread fill in seal material Teflon or seal pushes it's good to tighten the seal.

Installation Method
bottom of page